MyDro 150, 850

The Next Generation of Wireless Real-Time Alarm, Monitoring, and Remote Control

The MyDro 150 and 850 have all of the functionality of the M110 and M800, with an onboard interactive display and enhanced electronics. Each remote terminal unit (RTU) includes the necessary hardware for a standard installation—such as a cellular radio, enclosure, backup battery, transformer, antenna with cable and mounting hardware. Purpose-built RTUs simplify and speed installation. There is no programming required, and RTUs are self-enrolling.

View the comparison chart here.

Features:

Reliable Wireless Communications
RTUs operate on current generation cellular radios for dependable data transmissions. Mission maintains direct relationships with the largest cellular carriers in the U.S. and Canada to ensure the best service possible. There are no radios to license, nor cellular contracts to set up.

Real-Time Alarms Delivered To All Devices
Real-time alarms are delivered via phone call, text message, email, fax, page, and even to your existing HMI software via an OPC data link. Each alarm is logged with a timestamp for tracking and reporting. The alarm call-out schedule setup is easy, flexible, and intuitive—to be as simple or sophisticated as you want it to be.

Managed Service—The Complete Package
The Mission system includes all cellular data service, data storage, alarm call-outs, reports, and technical support that is on call 24-7-365. The highly reliable, turnkey system offers more features at a lower cost than an in-house setup. No engineering or programming is required and there are no networks to maintain.

View your data and reports using the included Mission 123SCADA software, accessible on your secure web portal from any web-enabled device. 123SCADA is the newest Mission user interface designed with the look and feel of industry-standard HMI SCADA that is packed full of new features as well as a legacy user mode. Tabular and graphical reports can be used for compliance reporting and comparative studies. As always, system enhancements are included at no cost and are immediately available.

MyDro 150 RTUs
Real-Time Alarms with Hourly Summaries
The MyDro 150 summarizes analog data, RTU status, pump run times, and pump starts hourly. All alarm data is reported in real-time. Simultaneous pump runtimes can be reported when two pumps run.

MyDro 850 RTUs
Real-Time Alarms and Streaming Data
The MyDro 850 reports pump starts and stops in real-time. Analog values are reported every two minutes or on a 5% change. Volumetric flow calculations can utilize this information along with sump volume (as determined by an analog level sensor or fixed entries) to calculate hourly volumetric flows.

Remote Control
Expand your system with optional remote control interfaces, such as automatically controlling offsite wells, tanks, gates, chlorine dosers, variable frequency drives (VFDs), and more, with optional remote control interfaces such as the Tank and Well Control Package, Digital Intertie, and Analog Intertie.

LCD Touch Screen
  • Displays current status
  • Supports local configuration
Radio
  • Cellular radios support LTE, 4G, 3G, and 2G for both GSM (AT&T and partners) and CDMA (Verizon and partners)
  • Dual SIM-capable radio
  • No radio licenses or site path studies required
Expandable
  • Up to 16 digital inputs, six analog inputs, two pulse inputs, and two analog outputs, all working simultaneously
  • Onboard digital inputs configurable for wire fault supervision or strap on load sensor for easier pump run indication
  • RS485 for digital, analog, and pulse expansion via expansion modules
Enhanced
  • 12 or 24VDC auxiliary output for battery-backed analog instrument loop power
  • Over-the-air upgradable firmware

Download Product Data Sheet

Technical Specifications

Model MyDro 150
Data
  • Alarm data: real-time
  • Pump information: pump run times and starts summarized hourly
  • Analog reporting: current value reported hourly
  • Device health: built-in inputs reported hourly
Input/Ouput
  • Digital inputs: eight on-board digital inputs (dry) with selectable wire fault supervision, or direct attach load sensor (for easiest pump run indication). Expandable to 16 with expansion modules. Three configurable for pump run summary reporting (number of starts and run time each hour). Simultaneous runtimes reported when two pumps are monitored.
  • Analog inputs: two on-board, 4–20mA "isolated" or 0–5VDC. Four alarm set points each. Expandable to six with expansion module.
  • Relay outputs: three remotely controllable, form C, dry contact relay outputs, 5amps at 30VDC, 120VAC, SPDT, N.O./N.C.
  • RS485: support for specified expansion modules
  • Pulse inputs: two channels with expansion module and 15 minute reporting
  • Electronic key reader: key reader for site activity tracking and service mode
  • Built-in inputs: AC voltage, battery voltage, board temp, and signal strength. Optional second (removal) key reader.
Electrical
  • AC power: supervised 120VAC to 12VAC, 1.2amp, UL-recognized class II / class III transformer
  • Backup power: 12V, 5AH battery standard, with enhanced charging system—up to 50 hours
  • Auxiliary: auxiliary output selectable 12VDC or 24VDC for battery-backed analog instrument loop powering—250mA max
  • Removable terminals, including: Amphenol PN 20020008-G061B01LF (6 pin for power), 20020004-D081B01LF (D08, D04, D03 for IO)
Other
  • Environment: operating temperature -20—75°C, non-condensing
  • Cellular radio: radios make live, continuous, encrypted TCP socket connections. Payload is end-to-end acknowledged. Penta band (850, 900, 1700, 1900, 2100 mHz.) AT&T and partners: LTE, HSPA+. 3G. Verizon and partners: LTE, EVDO, 1XRTT, dual SIM (carrier) capable.
  • Antenna: Omnidirectional antenna with 11' cable, SMA termination, universal mounting bracket
  • Options: optional SCADA integration OPC link (PN SW586) to client/server HMI, Tank and Well Control Package (see Accessories Brochure for more details)
  • Service: requires service packages for the unit and optional expansion boards (see Accessories Catalog for details)
  • Warranty: one year manufacturing and material warranty
Model MyDro 850
Data
  • Alarm data: real-time
  • Pump information: real-time
  • Analog reporting: every two minutes or on 5% change
  • Device health: built-in inputs reported hourly
Input/Output
  • Digital inputs: eight on-board digital inputs (dry) with selectable wire fault supervision, or direct attach load sensor (for easiest pump run indication). Expandable to 16 with expansion modules. Up to eight configurable for pump run. Pump states reported in real-time. Simultaneous pump runtime reporting supported for up to seven pumps.
  • Analog inputs: two on-board, 4–20mA "isolated" or 0–5VDC. Four alarm set points each. Expandable to six with expansion module.
  • Relay outputs: three remotely controllable, form C, dry contact relay outputs, 5amps at 30VDC, 120VAC, SPDT, N.O./N.C.
  • RS485: support for specified expansion modules
  • Pulse inputs: two-channels with expansion module and two minute reporting
  • Electronic key reader: key reader for site activity tracking and service mode
  • Built-in inputs: AC voltage, battery voltage, board temp, and signal strength. Optional second (removal) key reader.
Electrical
  • AC power: supervised 120 VAC to 12 VAC, 1.2amp, UL-recognized class II / class III transformer
  • Backup power 12V, 5AH battery standard, with enhanced charging system—up to 18 hours
  • Auxiliary: auxiliary output selectable 12VDC or 24VDC for battery-backed analog instrument loop powering—250mA max.
  • Removable terminals, including: Amphenol PN 20020008-G061B01LF (6 pin for power,) 20020004-D081B01LF (D08, D04, D03 for IO)
Other
  • Environment: operating temperature -20—75°C, non-condensing
  • Cellular radio: radios make live, continuous, encrypted TCP socket connections. Payload is end-to-end acknowledged. Penta band (850, 900, 1700, 1900, 2100 mHz). AT&T and partners: LTE, HSPA+. 3G. Verizon and partners: LTE, EVDO, 1XRTT, dual SIM (carrier) capable
  • Antenna: Omnidirectional antenna with 11' cable, SMA termination, universal mounting bracket
  • Options: optional SCADA Integration OPC Link (PN SW586) to client/server HMI, Tank and Well Control Package (see Accessories Brochure for more details)
  • Service: requires service packages for the unit and optional expansion boards (see Accessories Catalog for details)
  • Warranty: one year manufacturing and material warranty

You’re Never Alone

You will receive experienced technical support, including access to the people that built the system if needed. This includes comprehensive training, regular webinars, live support during business hours and after-hours support that is always available on a responsive callback basis for emergencies—at no extra charge.